TLA100 User’s Manual
Page 12 Revision 1.3
Mechanical
Parameter Value Comment
Size 3.9”” x 1.2” x 1.0” Excluding NMEA 2000
Connector & Cable
Weight 9 oz.
Mounting Any Orientation
Environmental
Parameter Value
IEC 60954 Classification Exposed
Degree of Protection IP67
Operating Temperature -25°C to 55°C
Storage Temperature -40°C to 70°C
Relative Humidity 93%RH @40° per IEC60945-8.2
Vibration 2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7
Rain and Spray 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8
Solar Radiation Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10
Corrosion (Salt Mist) 4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12
Electromagnet Emission Conducted and Radiated Emission per IEC 60945-9
Electromagnetic Immunity Conducted, Radiated, Supply, and ESD per IEC 60945-10
Safety Precautions Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
7 Technical Support
If you require technical support for Maretron products, you can reach us in one of the following
ways:
Telephone: 1-866-550-9100
Fax: 1-602-861-1777
World Wide Web: http://www.maretron.com
Mail: Maretron, LLC
Attn: Technical Support
9034 N. 23
rd
Ave Suite 13
Phoenix, AZ 85021 USA
Commentaires sur ces manuels