Maretron ACM100 Manuel d'utilisateur Page 1

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Moniteurs Maretron ACM100. Maretron ACM100 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Revision 1.2 Page i
®®
ACM100
Alternating Current Monitor
User’s Manual
Revision 1.2
Copyright © 2012 Maretron, LLP All Rights Reserved
Maretron, LLP
9014 N. 23
rd
Ave #10
Phoenix, AZ 85021-7850
http://www.maretron.com
Maretron Manual Part #: M001701
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - User’s Manual

Revision 1.2 Page i ®® ACM100 Alternating Current Monitor User’s Manual Revision 1.2 Copyright © 2012 Maretron

Page 2 - Revision History

ACM100 User’s Manual a. Connect the black wire to pin 7 (IA+) on the ACM100 b. Connect the white wire to pin 8 (IA-) on the ACM100 c. Disconnec

Page 3 - Table of Figures

Revision 1.2 Page 7 ®®will need to purchase an optional current sensor (Part # M000630) for monitoring this type of system. Step 1: De-ene

Page 4 - Table of Appendices

ACM100 User’s Manual 2.4.2.3 Three-Phase (Phase A, B, C) Connection Please refer to Figure 5 for connecting the ACM100 to a three phase system.

Page 5 - 1 Introduction

Revision 1.2 Page 9 ®®c. Disconnect the Phase B hot wire from the AC power source and place it through the hole in the Current Sensor such

Page 6 - 2 Installation

ACM100 User’s Manual Page 10 Revision 1.2 c. Connect the black wire from one end of the second Voltage Sense cable to pin 3 (VCLine) on t

Page 7 - 2.4 Connecting the ACM100

Revision 1.2 Page 11 ®®2.5.3 AC Circuit Type You must configure the ACM100 as to what type of AC circuit connection it is monitoring. The

Page 8

ACM100 User’s Manual Page 12 Revision 1.2 reconnecting the current transformer, you may change the value of this parameter from the defaul

Page 9 - Revision 1.2 Page 5

Revision 1.2 Page 13 ®®3.1 Line-Specific and Line-to-Neutral Measurements Parameter AC Source Type Available Data Bus Generator Utility

Page 10 - ACM100 User’s Manual

ACM100 User’s Manual Page 14 Revision 1.2 • Clean the unit with a soft cloth. Do not use chemical cleaners as they may remove paint or m

Page 11 - Revision 1.2 Page 7

Revision 1.2 Page 15 ®®6 Technical Specifications As Maretron is constantly improving its products, all specifications are subject to chan

Page 12

ACM100 User’s Manual Page ii Revision 1.2 Revision History Revision Description 1.0 Original document 1.1 Corrected AC sensor part numbe

Page 13 - Revision 1.2 Page 9

ACM100 User’s Manual Page 16 Revision 1.2 Electrical Parameter Value Comment Sensed Voltage 0-240 VAC 120,120/240,240,208Y,380Y confi

Page 14 - 2.5 Configuring the ACM100

®®8 Installation Template Please check the dimensions before using the following diagram as a template for drilling the mounting holes because t

Page 15 - 2.5.3 AC Circuit Type

ACM100 User’s Manual Page 18 Revision 1.2 9 Maretron (2 Year) Limited Warranty Maretron warrants the ACM100 to be free from defects in ma

Page 16 - 3 Output Parameters

Revision 1.2 Appendix A – NMEA 2000 Interfacing Page A1 ®®Appendix A – NMEA 2000® Interfacing ACM100 NMEA 2000® Periodic Data Transmitted

Page 17 - 4 Maintenance

ACM100 User’s Manual Page A2 Appendix A – NMEA 2000 Interfacing Revision 1.2 PGN 65005 – Utility Total AC Energy PGN 65018 – Generator Total

Page 18 - 5 Troubleshooting

Revision 1.2 Page iii ®®Table of Contents 1 Introduction ...

Page 19 - 6 Technical Specifications

ACM100 User’s Manual Page iv Revision 1.2 Figure 4 – Single-Phase (Dual Line) Connection Diagram ...

Page 20 - 7 Technical Support

Revision 1.2 Page 1 ®®1 Introduction Congratulations on your purchase of the Maretron Alternating Current (AC) Monitor (ACM100). Maretron

Page 21 - 8 Installation Template

ACM100 User’s Manual Page 2 Revision 1.2 o 230VAC single phase o 380VAC Y Three-phase (380Y) 1.3 Quick Install Installing the Maretron

Page 22

Revision 1.2 Page 3 ®®2.3 Mounting the ACM100 Attach the ACM100 securely to the vessel using the included stainless steel mounting screws

Page 23 - Interfacing

ACM100 User’s Manual Figure 2 – NMEA 2000® Connector Face Views 2.4.2 AC Sensor Connections The ACM100 sensor connections are made by connectin

Page 24

®® WARNING: If the supplied current transformer is placed around a wire carrying AC current, then extremely high voltages can develop on the out

Commentaires sur ces manuels

Pas de commentaire